The Silver/Silver Chloride electrodes are manufactured using an advanced technique that results in a porous silver matrix being formed around a silver wire skeleton. The matrix is then coated with precise quantities of Silver/Chloride to ensure:
- HIGH STABILITY
- GREATER ACCURACY
- INCREASED LIFE PERFORMANCE
NOTE The Silver/silver chloride element in the Reference Electrode is directly exposed to the Seawater; hence these reference electrodes are not suitable for use in any other medium. It is recommended that the CCS1 electrode be assembled inside in a protective UPVC or equivalent housing for mechanical protection. Also clamp for support on structure offer as per project design.

Typical Applications
Sea water applications, Offshore, Marine terminals etc.
FEATURES
Cable
Cross section:
- 4sqmm
- 6sqmm
- 10sqmm
Insulation:
- XLPE/PVC
- HMWPE
- H07RN-F
Armor:
Length: 60m
Outer Casing
Material: ACETAL
Length: 110mm
Diameter: 22mm
Silver Chloride Element
Length: 50mm (+/-2mm)
Section: 5mm x 5mm
Geometric Surface Area: 10cm2
Real Surface Area: 500cm2
Materials: Silver Compounds are 99.90% pure
Performance Data
Stability (Potential drift at constant temp and environment): +/- 1mV (24 Hrs) @ 5 micro Amp load
Accuracy ( Vs SCE in 3% NaCl @ 200C): -5mV +/- 5mV
Temperature Coefficient: -0.65mV/Deg C
Life for use in Seawater
Permanent: 50 Years (Theoretical) @ 0.1μA load
Temp Range: -5 to 70OC